Stovax Stove 7125F User Manual

Stockton 7  
Inset Convector Stove - Smoke Control Version  
MODeLs: 7125F  
Instructions for fitting smoke control kit  
For use in Gb (Great britain)  
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated  
instructions and in some cases the appliance will require modification. Contact Stovax for further information.  
IMPORTANT  
This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the  
protection of young children, the elderly or infirm. Do not attempt to burn rubbish in this appliance.  
Please read these Instructions carefully before installation or use.  
Keep them in a safe place for future reference and when servicing the fire.  
The commissioning sheet found on page 3 of the main instructions should be completed by the appliance Installer.  
These INsTRucTIONs MusT be useD IN cONjuNcTION wITh PM230  
PM281 -Issue 1 (January 2009)  
 
useR INsTRucTIONs  
the fire.  
Compact stacking will make the wood burn slower as wood  
can only reach the outside of the fire. This will cause the  
fire to smoulder and produce smoke.  
4.2 Experience establishes settings to suit personal preferences.  
4.3 Do not burn large amounts of fuel with the Airwash con-  
trol closed for long periods of time. This reduces the glass  
cleaning effect and causes tars and creosotes to build-up in  
the appliance and flue system and will produce excessive  
amounts of smoke.  
Air Inlets  
Log Guard  
4.4 When in use, burning the appliance at high output for a  
short period also reduces tars and creosote.  
• Close the door  
When running the appliance:  
• Burn new logs at high output for a few minutes before  
adjusting the Airwash control.  
Do not leave the door open as this could over-fire and  
damage the appliance.  
Refuel little and often for clean, efficient burning.  
4. RuNNING The APPLIANce  
A bright and clean firebox indicates the appliance is  
burning well.  
4.1 burning wood:  
• Close the Primary air control and use the Airwash to  
control the burn rate when appliance is at operating  
temperature, Diagram 4  
• Add a small amount of kindling and open the air controls  
if the firebed is low when the appliance is refuelled  
This helps re-establish the fire. Do not close the air controls  
until the fire is burning well.  
4.5 Do not load fuel above the log guard and the secondary  
combustion inlets at the back of the firebox.  
Diagram 3  
Air wash: Adjust  
• Wood burns best on a bed of ash  
• Rake the embers evenly over the fire bed and open the  
Airwash control fully for a few minutes before re-fuelling to  
establish a glowing bed of coals  
• Stack the logs in an open arrangement, Diagram 5  
Open Stacking  
Compact Stacking  
Open stacking allows oxygen to easily reach every part of  
3
 
INsTALLATION INsTRucTIONs  
These instructions cover the fitting of the Smoke Control Kit  
2.4 Replace the Airslider with the Smoke Control version,  
1. PARTs LIsT  
Diagram 10  
• Smoke Control Air slider (Stovax Part No. ST5SCKIT)  
Air slider  
2. INsTALLATION  
2.1  
To install the Smoke Control kit:  
• Remove internal packaging and Log Guard, Diagram 7  
Airwash Chamber  
2.5 Fitting is the reverse of the above  
2.6 Ensure the Air slider screws are tightened to a tension that  
ensures movement when the Airwash is operated. The Air  
slider must be positioned correctly and not rest on the inlet,  
Diagram 11  
Gap  
2.2  
Remove the two bolts on the Airwash chamber  
These are located on the inside of the stove, Diagram 8  
Inside the appliance  
Incorrect  
Correct  
2.7 Replace packaging  
Airwash  
Chamber bolts  
Airwash  
Chamber bolt  
2.3 • Rotate and pull the Airwash chamber through the front of  
the appliance to remove, Diagram 9  
Airwash  
Chamber  
4
 
 
stovax Ltd, Falcon Road, sowton Industrial estate, exeter, Devon, england eX2 7LF  
Tel: (01392) 474011 Fax: (01392) 219932 e-mail: [email protected] www.stovax.com  
 

Sennheiser Musical Instrument EM 3731 User Manual
SMSC Network Card LAN1198 User Manual
Soleus Air Air Conditioner SG CAC 08ESE User Manual
Sonance Speaker ST2416S Series User Manual
Sony Cassette Player CFS 616L User Manual
Sony Digital Photo Frame DPF C1000 User Manual
Sony Headphones CPF IP001 User Manual
Sony Headphones MDRZX100 User Manual
Sony Portable Speaker SRS Z1000PC User Manual
Sony Security Camera Network Video Monitoring User Manual